Customization: | Available |
---|---|
After-sales Service: | Customized Services Are Available |
Warranty: | 5 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Solis Three Phase Inverters
S5-GC(25-50)K
400V: 25K/30K/33K/36K/40K/40K-HV/50K-HV
S5-GC(25-50)K three-phase series string inverter adopt 3/4 MPPT design to provide a more flexible configuration scheme with a smaller environmental impact rate and higher generation efficiency. Whose operation is so quiet, like a whisper, thus creating a more comfortable and friendly working and living environment.
**
DATASHEET S5-GC(25-50)K |
|||||||
Models | 25K | 30K | 33K | 36K | 40K | 40K-HV | 50K-HV |
Input DC | |||||||
Recommended max. PV power | 37.5 kW | 45 kW | 49.5 kW | 54 kW | 60 kW | 60 kW | 75 kW |
Max. input voltage | 1100 V | ||||||
Rated voltage | 600 V | ||||||
Start-up voltage | 180 V | ||||||
MPPT voltage range | 200-1000 V | ||||||
Max. input current | 32 A / 32 A / 32 A | 4*32 A | |||||
Max. short circuit current | 40 A / 40 A / 40 A | 4*40 A | |||||
MPPT number/Max. input strings number | 3/6 | 4/8 | |||||
Output AC | |||||||
Rated output power | 25 kW | 30 kW | 33 kW | 36 kW | 40 kW | 40 kW | 50 kW |
Max. apparent output power | 27.5 kVA | 33 kVA | 36.3 kVA | 39.6 kVA | 44 kVA | 44 kVA | 55 kVA |
Max. output power | 27.5 kW | 33 kW | 36.3 kW | 39.6 kW | 44 kW | 44 kW | 55 kW |
Rated grid voltage | 3/N/PE, 220 V / 380 V, 230 V / 400 V | 3/PE, 480 V | |||||
Rated grid frequency | 50 Hz / 60 Hz | ||||||
Rated grid output current | 38.0 A / 36.1 A | 45.6 A / 43.3 A | 50.1 A / 47.6 A | 54.7 A / 52.0 A | 60.8 A / 57.7 A | 48.1 A | 60.1 A |
Max. output current | 41.8 A | 50.2 A | 55.1 A | 60.2 A | 66.9 A | 53.0 A | 66.2 A |
Power factor | >0.99 (0.8 leading - 0.8 lagging) | ||||||
THDi | <3% | ||||||
Efficiency | |||||||
Max. efficiency | 98.5% | 98.6% | 98.7% | 98.8% | |||
EU efficiency | 98.1% | 98.2% | 98.3% | 98.4% | |||
Protection | |||||||
DC reverse-polarity protection | Yes | ||||||
Short circuit protection | Yes | ||||||
Output over current protection | Yes | ||||||
Surge protection | DC Type II / AC Type II | ||||||
Grid monitoring | Yes | ||||||
Anti-islanding protection | Yes | ||||||
Temperature protection | Yes | ||||||
Strings monitoring | Yes | ||||||
I/V Curve scanning | Yes | ||||||
Integrated AFCI (DC arc-fault circuit protection) | Yes (1) | ||||||
Integrated PID recovery | Optional | ||||||
Integrated DC switch | Optional | ||||||
General Data | |||||||
Dimensions (W*H*D) | 647*629*252 mm | ||||||
Weight | 37 kg | ||||||
Topology | Transformerless | ||||||
Self-consumption (night) | <1 W | ||||||
Operating ambient temperature range | -25 ~ +60°C | ||||||
Relative humidity | 0-100% | ||||||
Ingress protection | IP66 | ||||||
Cooling concept | Intelligent redundant fan-cooling | ||||||
Max. operation altitude | 4000 m | ||||||
Grid connection standard | G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 / UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, EIFS 2018.2, IEC 62116, IEC 61727, IEC60068, IEC 61683, EN 50530 |
||||||
Safety/EMC standard | IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4 | ||||||
Features | |||||||
DC connection | MC4 connector | ||||||
AC connection | OT terminal | ||||||
Display | LCD | ||||||
Communication | RS485, Optional: Wi-Fi, GPRS |